Even heat distribution. . Electric hobs are compatible with any material but it’s important the bottom of. I've added a couple of wiring options. Buy any 10+ Save 10% - View Offer. A 3kW kettle is only on for say 2 or 3 minutes at a time, whereas, a hob could be on for an hour or more at a time. €91. seneca Screwfix Select. £289. 0kW) had been wired to just one 20A supply - the other one is unused - but live. 2 x Plate Sizes. You simply want to find out which fuse is on the Oven circuit and what its rating is (guessing 32A). 2 x Ceramic Plates. Dimensions: (H)6cm x (W)60cm x (D)53cm. The induction hob will require max of 6kw/240v = 24 amp. 3 KW (max. . 5MM2. Yes, as pointed out above. Hobs Sort By: Cooke & Lewis CLCER60a Ceramic Hob Black 52mm x 590mm (277GX) (94) compare 4 x Ceramic Plates 2 x Plate Sizes Child / User Safety Control Lock. Hi all. This is why 3kW immersion heaters are on separate circuits. I have a 6mm cable from my cu to a cooker connecter box via a 45 dp switch which protected by 30A fuse, I want to wiring in a 5. Child Safety Lock Mechanism. Unlike gas hobs, there are several types of electric hob, and choosing the right one for you can be confusing. MGW Screwfix Select. C. Please do not return to store. Buy Cable at Screwfix. Free next day delivery available. It will need a 13A fuse, which will come with it. Buy online and collect in store in as little as 1 minute. The designer of the circuit has determined that the 32 amp MCB is the suitable OPD for the circuit. Should the product require repair please contact our repair service to arrange collection and repair. UK call centre ready for your call 24/7. The problem is on the connection block there are 2 blue wires side by side L1 & L2 and a black wire at the end L5 just wondered if anyone had any idea where the earth cable goes? Many thanks Mikeunphased Screwfix Select. €98. Those who increase the cable size to 10mm2 are unfamiliar with domestic cooker circuits and are wasting money; it wont achieve any benefit whatsoever. Discussion in 'Electricians' Talk' started by alex250, Aug 1, 2004. Is that correct?. Hi, Cheers for the quick response. stateit Screwfix Select. sinewave Screwfix Select. Screwed Faceplate. AEG HKB64450NB 60cm Gas Hob, Black. Raised Square Profile. 4. 49 Inc Vat. Cooker is reactivated by resetting the system once the cause of the alert has been investigated and controlled. Screwfix Select. the thicker one is the hob. Take a spur off a socket above the worktop as a feed to the new single socket. Some folks also would just wire microwave socket from kitchen ring too. Automatic switch-off timer and up to 9 adjustable power levels per zone. PayPal accepted online. To assess the loading of the hob and oven do the following. Control Type: Touch. Requires 46mm Back Box. I can't fit the brackets as the underneath edges of the hob are sat too close to the wooden struts. Order Cooke & Lewis CLCER60a Ceramic Hob Black 52mm x 590mm at Screwfix. Miele KM7201FR Electric Induction Hob - Black. Product Width. If you must go the FCU route then just go on the Screwfix site and type FCU in the search box. Scolmore is a brand with a very good reputation, and the link you give has a price for it that none of the wholesalers I have accounts with could. Total Product Weight. Cooke & Lewis GASUIT4 Gas Hob Stainless Steel 83mm x 580mm (420FH) (76) compare. Hi there. Screwfix Community Forum. Order Cooke & Lewis CLIND60 Induction Hob Black 68mm x 590mm at Screwfix. 49 Inc Vat. Page 1 of 2 1 2 Next > Thread Installing 2 ovens, an induction hob and a microwave. 5 mm flex seemed a bit lightweight for the hob. One wire in the Left hand terminal looks a bit dodgy. Bostik FP401 Fire Resistant Acrylic Sealant White 310ml (572JE) compare. Our Lowest Price Ever. Hello, got a new induction hob to replace an old electric hob (the old style with raised heat elements that take an hour to heat up then 3 hrs to cool down) it is all plumbed in with a big red switch and theres a junction box behind the cooker for easy change over, just wanted to know is it just a case of connecting the right wires up and. I hope this the right thread. 0800 324 7818. Buy online and collect in store in as little as 1 minute. Looking at gas hobs that are 75 x 51 cm the holes required are. Screwfix Community Forum. 3 KW (max. Order Cooke & Lewis CLIND60 Induction Hob Black 68mm x 590mm at Screwfix. As others have said, look for the rating label on the hob, to use a 13A plug successfully it should not exceed 3. If it works with L1 and L2 together, with the marking of “25A” usually meaning per phase, it is going to give 50A on the neutral at full load. all 3 requie hard wiring. FREE next day delivery available, free collection in 1 minute. kitfit1 Screwfix Select. 97 » View product. 7Kw so by my calculation that means the maximum current in the circuit = 10700/230 = 46. 3 kw 10 ampI currently have an Electric oven on a cooker circuit with a 32 AMP MCB and a Gas Hob on the Kitchen circuit with a 32 AMP MCB. Screwfix Community Forum. 49 Inc Vat. LAP 45A 2-Gang DP Cooker Switch & 13A DP Switched Socket Black Nickel with LED with Black Inserts (96338) (22) compare. 99Inc Vat. Order Cooke & Lewis CLCER60a Ceramic Hob Black 52mm x 590mm at Screwfix. 43a 7000w. We have a need to relocate the isolator switch as it will clash with a new kitchen layout. . I want to get a new hob. Is there a minimum distance required between the back of the electric oven and the copper gas pipes. Please do not return to store. Most gas supplies I have seen come from below the working height and hence not near the actual hob ring. Allow to dry between coats. The AEG Pure 3 hob combines a sleek, seamless design with responsive functions. 7 KW) Induction or 2 x Ø 190 mm, 2. Each cooking plate has a separate neon indicator and the base of the hob. The hob is sat right on top of the ovens and there is a small gap between the hob and the worktop at the front (see attached pics) Now its all. It also says 380 to 415V between L1 and L2. cliffk said: ↑. If I remember my 3-phase theory (that was a long time ago) current in neutral = Phasor sum of the 3 phase currents. CDA 30cm 2 Zone Domino Ceramic Hob. 6a then 30% of fl remaining 10. Do they go any bigger and would it be feasible to fit. Screwfix Community Forum. 47 amps. 5MM2. It took me some time to work out what had casued it (none of the independant switches had tripped) but it wouldn't re-set. Only £179. It will most likely have a 45A switch on it. Please do not return to store. Raised Rounded Profile. British General 900 Series 13A 2-Gang SP Switched Plug Socket White 5 Pack (48563) (62) £13. " i. 2 x Ceramic Plates. Cuts off the electricity supply if the hob has been left on accidentally. Cooke & Lewis CLCER30A Ceramic Hob Black 60mm x 290mm (777FK) compare. So in your case we would have 3. 04 amps then add the the first 10 amps back on, total with diversity taken into account = 20. You can simply swap the existing outlet plate for the dual one and wire both appliances off it. This oven was in the tower cabinet which has ventilation at the back of cabinet and now I want to move this oven to the 'under the gas hob' position. 56A) = 20. T+E cable, what a want to know is can both new Bosch appliances be hard wired to a ( cooker ) twin junction box by. Deals and Offers. In Stock. sinewave, Oct 4, 2010. £72. Add to wishlist. Quick installation via an existing socket or alternatively can be hard wired by a qualified electrician for full functionality. Pay your way. Transform the kitchen and turn cooking. Wiring a 7. Next to the sticker is a black plastic panel which covers the hole where the wire goes. Home Forums > Screwfix Community Forum > Electricians' Talk > New Electric hob. 5mm2. #4. 98. What sealer is most appropriate? This will be on the surface of the worktop so should be simple to remove later on if needed. Which is what you require. Warranty: 2 year warranty. Apple Pay accepted in store. Home Forums > Screwfix Community Forum > Plumbers' Talk > Propane Gas Hob. If you come up with a figure of much more than 32 amps don't panic, it could still be ok if diversity is taken into account. Brown, Blue & Green/Yellow Cores. 79Inc Vat. 4. Electric and gas options make classic choices, while induction is. 4KW 13Amp) as it is on its own 32Amp breaker and calculated with diversity (this was from online appliance advisor). The oven is just plug in but the hob needs hard wiring. Durable and easy to install. Repair Service Action. Check the overall measurement of your new hob to see if it will. £438. I think the hole is too big so not sure if I have to buy a large gas hob to cover space. The Sigma3 countertop depth is the standard 600 mm but the splashback thickness (approx 15 mm) clearly reduces the useable depth to less than the minimum 600 mm required by Neff. I went from gas to induction hob and wouldn't go back. £72. Now obviously this is not good and ive recommended a different layout of the kitchen and to try get the hob above some cupboards where. Easy-Tear. kitchen appliances. Delivered by our approved supplier, Find out more. Sparkielev said: ↑. Discussion in ' Electricians' Talk ' started by Curiouscat, Jan 26, 2009 . Double 13A sockets are only designed to handle 20amp. The new induction hob has 10, 13, 16 & 20 Amp power options with max 7. Hob Type: Induction Hob. 7 Strands Per Core. I have a electric hob (input 5500W) which my electrician has connected to the cooker switch using a 6mm T+E cable. Buy any 10+ Save 10% - View Offer. Warranty: 2 years labour/5 years parts. Child Safety Lock Mechanism. As the electrician is busy. "drop test " on the meter to make sure that the. Over 40,000 products. It's explained in the hob manual. Cool White. Home Forums > Screwfix Community Forum > Electricians' Talk > New Hob. Pay no interest when you pay your full balance within 9 months 29. These days gas hobs come with 13amp plugs. I already have one on the kitchen wall which feeds my fan oven. 1 x Ø 380 mmx230 mm, 3. Hisense BI64211PB Built-in Single Multifunction pyrolytic Oven - Black. 2. Ask a question. The old units are both wired into a CCU, hob - 6mm cable, oven 2. Includes baking tray, trivet and shelf. The process you describe above is more like how a microwave oven works. Hi there. Screwfix London Victoria. I replaced my electric hob with a gas one today. Hi All, I've just wired in a hob and only two of the rings are working. 5kW blasting away in all. I want to run the cable from the kitchen to the cupboard where the consumer unit is myself and then get the electrician to install the ovens and hob at one end and do the work on the consumer unit (we may need a new consumer unit but the electrician sill sort all that out). #8. If the whole area is grimy, then use a toothbrush with the WD40 to clean thoroughly around the button shaft and wipe it clean. Add to wishlist. Is there a minimum distance required between the back of the electric oven and the copper gas pipes. Odourless. 5mm, does this mean I use a 2. According to Neff, for the hole cut out of the worktop, the minimum front and back distances from hob to back wall and front edge to counter are 50mm (front) and 55 mm. PayPal accepted online. Free next day delivery available. 5 mm cables. Only £578. Pay no interest when you pay your full balance within 9 months 29. #2. I have an existing 6mm cooker cable direct from the consumer unit approx 10M long currently protected by 32a mcb. In practice, 15mm will make little, if any, difference. Number of Cooking Zones: 4 Zones. 29 Inc Vat. Safety Gas Cut-Out. We’re replacing our gas oven with an electric oven but keeping the gas hob. Screwed Faceplate. Hello, I am having a new electric single oven and induction hob delivered. Where two stationary cooking appliances are installed in one room, one. You can make up some brackets using fixing plates or angle brackets, just take care that the screws don't pierce anythng inside the hob. There is a switch on wall by oven. Total 40 amp. Choose from top trade brands. rogerk101 Screwfix Select. From the photos, it’s pretty clear that the glass cooktop has detached from the frame that holds it into the recess. Add to basket. Bob Rathbone Screwfix Select. IMHO, all gas hobs are technically identical, nearly, the money goes into pan support etc. You don’t actually need a wide bead to seal, although you can, just a tiny bit of sili in the mm or so gap. From the photos, it’s pretty clear that the glass cooktop has detached from the frame that holds it into the recess. The current electric hob surface dimension is 77 x 51 cm with the hole being 75. 29 Inc Vat. 60a - 10a = 35. Bought the cheapest 4 zone non branded on Appliances Direct and it's been fine now for 5 years or so, we paid about £150 for it then. 1kW and we’re installing a new dual fuel range oven rated at 8. 3 x Burner Sizes. However, the oven will still not fit because of a pipe coming down from the hob itself. The old units are both wired into a CCU, hob - 6mm cable, oven 2. Add to basket. I originally thought this meant to use either 5 or 3 cables. If it needs hardwiring, get a dual appliance connector plate. Promote a healthy airflow. Most CERAMIC hobs are rated above 3kW and also require a 32A radial circuit. 00. The switch will act as an isolation switch for both. Start at the MCB, then look at the isolation switch, the connection to the hob and any other strange junction that the LL or his skilled assistants may have introduced. The touch panel controls are not working to increase, lower or shut down the hob. 590 mm. Touch-operated ceramic hob ideal for smaller cooking areas. 2 kg. 3500w for 16A input. The strip has to go on the edge of the appliance, then trim the excess off, very gently, as not to scratch the hob or work surface. Single oven yes. Hotpoint TQ1460SNE Electric Induction Hob - Black. Once you have cut the pipe then you will need to do a. The product manual does not state the cable size to the hob, only that it should be H05BB-F or H03V2V2-F. 2KW which is 32 Amps, the oven is on top of that. This Zanussi four variable zone ceramic glass hob, is not only stylish but easy to clean with residual heat indicators, meaning it's clear when it's safe to. Extract and recirculate kitchen steam and fumes. If your induction hob comes with a factory fitted 13A UK plug, then you can plug it in to the standard UK socket using its factory fitted plug. 5mm cable, but you need to change some jump connections on the unit itself depending on the power source; But it will not work at full capacity which defeats the. Both the hob and the oven can pull their maximum current of 2 x 13 amp (26amp). The technical data states, conductors (number & size)3 x 2. 3 phase supplyHi need bit of advice hope you guys can help recently bought a new Neff double oven,electric hob and microwave,all 16amp rating 240 volt. Buy any 10+ Save 10% - View Offer. At present the oven is hard wired into a connection plate at the back of the oven. However, he seems to have second throughts. It's a new build, only 4 years old and has been fine. Buy Air Vents at Screwfix. 85 kg. 5kw respectively. Large Capacity Easy to Wire Terminals. Agreed UP, 10mm for a standard domestic cooker circuit is a total waste of money (and copper!) seneca, Feb 28, 2017. alex250, Aug 1, 2004 #1. 5MM2. Before I contact the manufacturers I'd thought I'd seek your help. Timer. Buy online and collect in. All on a 40amp breaker or would it be best to de-rate down to. (Gas CH/HW still needs electricity. These screw guns are ideal for domestic projects such as. Yes, they would work perfectly well if plugged in on a 13A socket but the circuit would quickly overload when other appliances were plugged in. HOTDOG ø, May 26, 2008. Available in several different options. Hobs however, usualy require a dedicated 4/6mm 32A+ supply. Supplied with wall-mounting bracket. Would it be possible to install it on our existing power setup for the oven?recently wired a cooker supply expecting there to be a gas hob and oven . Works out when the temperature of cooking is too high and turns off the source of ignition, effectively preventing kitchen fires before they start. 5kw for the hob, a total of 10kW. Filters. Hi Seneca thanks for your swift reply, The Hob is 6. Products reviewed by the trade and home improvers. 49 Inc Vat. If so, spray - ideally with a straw - a small amount on that shaft and press the button repeatedly downwards. Two out of four elements in my electric hob have gave up the ghost. Flat or raised surfaces for cooking. Products reviewed by the trade and home improvers. Stock Number ES1781989. No Timer Function. 3000w for 13A input. Product information. Cooke & Lewis CLCER30A Ceramic Hob Black 60mm x 290mm (777FK) compare. £ 5. #2. com. I would like to have them replaced by by both electric hob and electric oven. 99 More info. Thread by: Aimee88 , Feb 4, 2022 , 6 replies, in forum: Electricians' Talk Showing results 1 to 1 of 1Hendo New Member. 00. (70) From £90. I have and electric cooker hardwired into a cooker point that is within 2m of the cooker - i also want to put and electric induction hob on the other side of the kitchen, i will but putting in a separate feed does this also have to have a cooker switch and does it need to be visible? Neither a cooker nor a hob need isolation. Why not put the cabinet in that the integrated oven will sit in then fit the oven. sfrazi New Member. My first question is: is there any issue with having the hob on the same circuit as the kitchen sockets? It also says 380 to 415V between L1 and L2. A user asks how easy it is to change an electric hob for another one at home. MGW Screwfix Select. I was advised the new gas hob requires a hard copper connection. £77. I do not have the luxury of being able to run a new cable from the CU, not without a lot of disruption to many rooms. 5 mm cables or 3x2. Total Product Weight. 85Kw (45. 590 mm. LOGIK LCHOBTC23 59 cm Electric Ceramic Hob - Black. Dr Bodgit, Oct 24, 2017. A hob separator plate is a piece of sheet metal installed on the underside of your hob. Quantity: FREE Click & Collect within 30 minutes. When I switch the hob back on at the fuse board, it's ok again, but trips at a random time, even when not in use. 85 kg. Touch-Dry in 1-2 Hours. The work top is 600mm. Screwfix customers rate this product 4. Pay your way. I have checked the specification re your comment "must be a small hob" The Neff hobs have a power management menu. 0800 324 7818. £109. Coloumb Screwfix Select. MGW Screwfix Select. 2 KW. View all: No Nonsense Spray Paints. 0800 324 7818. Wife's son as give me an induction hob he as had given, to install. So technically there are 3 wires to connect. We have the hob on top of two single ovens. Total Product Weight. Plug the new oven in. Repair Service Action. London. 9% APR representative (variable)* +1 more offers. British General 900 Series 45A 1-Gang DP Cooker Switch White with Neon (67918) (26) £7. There needs to be a gap of at least 65cm between your hob and the cooker hood or ceiling. Also, there is a burning smell and some fumes coming out from under the hob and between the gap in. Davie Active Member. Features 4 functions including grilling and plate warming. Cooke & Lewis CLIND60 Induction Hob Black 68mm x 590mm. Discussion in 'Electricians' Talk' started by Ozwald Cobblepot, Sep 11, 2022. Looks wired correctly. Hob. Some hobs come with cable, some don’t. #26. Easy to clean. 00. leaks. Most are under 3 kW (approx rating for a 13A plug) 4 ring hob, probably not; unless it's a 2 ring 'domino hob' pulling less than 3 kW. On the new Beko hob it simply states use 5x1. 3/5. Currently in my kitchen we have a range cooker with an electric oven and a gas hob. com. Nomad24 New Member. Our current gas oven depth is 523mm & the depth of the electric oven is 560mm. 47 x 30 % =10. Those who increase the cable size to 10mm2 are unfamiliar with domestic cooker circuits and are wasting money; it wont achieve any benefit whatsoever. 6kW) and Ceramic hob (7. All we need to know is what the rating for the oven is! Bazza, Mar 31, 2021. Hi Both front and back left hand side of hob wont work, both rings on right hand side is fine. PAGE 1 OF 12. Discussion in 'Electricians' Talk' started by SpuddyMcFuddy, Nov 14, 2017. Electrical connection 3. Touch-Dry in 1-2 Hours. So I think I can just plug the oven into the ring main and use the 32amp feed for the hob. Work out the total power in W of both units, for you that is 6000W + 4200W, = 10200W then divide by 230V = 44. Instructions say hob must be connected to a fused spur outlet with 3A fuse and oven must be connected to a fused spur outlet with 13A fuse (using 1mm cable). 4. 45 kW - new combi microwave oven is 3600W (it states it must be hardwired with a 16 Amp fuse)The cupboards, shelves etc above the hob are not allowed to overhang the hob, so a 600mm hob needs a 600mm minimum opening above it. Induction Hob. (41) 5. Yes, they would work perfectly well if plugged in on a 13A socket but the circuit would quickly overload when other appliances were plugged in. Oven is 880mm. Buy Cooker Hoods at Screwfix. Home Tags > hob. Huge range of cap fittings, shapes, wattages and technologies. stateit, Jan 11, 2014. According to Neff, for the hole cut out of the worktop, the minimum front and back distances from hob to back wall and front edge to counter are 50mm. Add for Delivery.